ZR and ZP are the two Copeland scroll families UAE technicians deal with daily. The distinction is refrigerant: ZR compressors are designed for R22 (and R407C-type blends), ZP compressors for R410A. Because R410A runs at around 1.6 times the pressure of R22, the two families are engineered differently and are not interchangeable.

Comparison

ZR seriesZP series
RefrigerantR22, R407C-typeR410A
Design pressureLower (R22 pressures)Higher (R410A pressures); reinforced shell and scroll set
OilMineral / alkylbenzene (POE on some newer variants)POE
BOTANVÈ capacity range3.5–12 HP (ZR42–ZR144)2.6–6 HP (ZP36–ZP72)
Typical use in UAEReplacement in older splits, ducted and package unitsReplacement in R410A splits and ducted units installed since ~2010
Price range at BOTANVÈAED 980–2,850AED 1,274–1,775

Can you convert from ZR to ZP?

Converting an existing R22 system to R410A (ZR to ZP) requires changing the compressor, expansion device, and flushing and recharging with POE oil — the copper lines can often be reused if they are the correct diameter and in good condition. This is a significant job and is typically only worthwhile if the rest of the system (coils, controls, piping) is in good condition. For most UAE maintenance scenarios, like-for-like replacement (ZR for ZR, ZP for ZP) is the standard approach.

Single-phase vs three-phase

Copeland ZR and ZP compressors are available in both single-phase (PFJ electrical code, 220–240 V) and three-phase (TFD, 380–420 V) variants. The single-phase range covers smaller capacities (typically up to about 5 HP); larger compressors are three-phase only. Check the existing unit's electrical supply before ordering a replacement — a three-phase compressor cannot be run on a single-phase supply. BOTANVÈ stocks both variants; specify the electrical code when ordering.

See the model number guide to decode every field of the Copeland part number, and the Copeland brand page for all models stocked by BOTANVÈ.

Can a ZP replace a ZR?

Only as part of a full conversion to R410A, which means the entire system — coils, expansion device, line set wall thickness, filter drier and oil — must be rated for R410A. In practice, that is a new unit. For an R22 system, replace ZR with ZR; for an R410A system, ZP with ZP.

Selecting within each family

  • Match rated capacity (BTU/h or kW) to the original, not just the nominal number in the code.
  • Match the electrical code (PFJ/PFZ single phase, TFD three phase) — see reading Copeland model numbers.
  • Check suction/discharge connection sizes on the product page against your line set.
  • Confirm oil type and charge from the spec table.

Models at BOTANVÈ

ModelCapacityPrice
Copeland ZR42K3E Scroll Compressor35,000 BTU/hAED 1,000
Copeland ZR61KCE Scroll Compressor49,700 BTU/hAED 1,200
Copeland ZR94KCE Scroll Compressor79,500 BTU/h (6.63 TR)AED 2,350
Copeland ZP36K5E Scroll Compressor2.6 HPAED 1,286.62
Copeland ZP51K5E Scroll Compressor4.6 HPAED 1,588
Copeland ZP72KCE Scroll Compressor6.0 HPAED 1,775

Prices are BOTANVÈ catalogue prices in AED including VAT at the time of writing (2026-08-30); they change with supplier costs and exchange rates — the product page always shows the current price.

Buying for a project or in volume?

Upload your BOQ or model list and BOTANVÈ will quote HVAC-R pricing, stock and UAE delivery.

Frequently asked questions

Is ZP better than ZR?

Neither is 'better' — they serve different refrigerants. ZP is the correct choice for R410A systems; ZR for R22 systems.

Can I use ZR with R410A?

No. ZR compressors are not rated for R410A pressures.

Why is the ZP range smaller at BOTANVÈ?

It reflects current stock; other ZP capacities can be sourced — ask on WhatsApp.

Which oil does a ZP use?

POE (polyolester) oil; the charge is listed in the product spec table.